Discussion:
hull flush sewage connectors
DBA Forum (B) - David Beaumont
2014-10-14 23:22:03 UTC
Permalink
Is there some standard for a sewage hose to hull removable connection which, when disconnected, is flush with the hull?

Bit late now as I am making one by welding a 1" female D Camlock to a 1 1/2" male nipple (sorry but those are the correct terms). I do wonder if I am re-inventing the wheel but can't find anything.

Hopefully pontoon side the standard is 1" Camlocks anyway that is what our marina have gone for.

David
DBA Forum (B) - Jeremy May
2014-10-15 05:13:04 UTC
Permalink
Is this the type of thing David?

http://www.midlandchandlers.co.uk/Catalogue/ProductDetail/pump-out-socket-brass?productID=38f143c5-13f1-494a-a4da-fd8e59ab7956&catalogueLevelItemID=22263c90-6035-4601-b9e4-a88d3c3e717e
DBA Forum (B) - Colin Stone
2014-10-15 06:34:02 UTC
Permalink
Yes - an ISO standard flush deck fitting fitting which will accept the male suction nozzle at a pump out station or 1 1/2 inch BSP threaded male fitting.
So work everywhere.

Colin Stone
KEI

Sent via BlackBerry® BIS
DBA Forum (B) - David Beaumont
2014-10-15 09:40:35 UTC
Permalink
Will that accept a semi permanent and airtight hose fitting on the outside though?

David
DBA Forum (B) - Colin Stone
2014-10-15 10:08:03 UTC
Permalink
David,
Post by DBA Forum (B) - David Beaumont
Will that accept a semi permanent and airtight hose fitting on the outside though?
Yes - I use a 1 1/2 male BSP hosetail to make my own pump out fitting.

Thumbnail pic of trash pump pumping here:

www.luxe-motor-kei.co.uk/oxcruisers/oxcruisers2.html

Water feature. Large pic gone astray.

Colin Stone
KEI
Sent via BlackBerry® BIS